General provisions for the design of residential staircases and lifts
Release time:
2022-06-16
The stairwell design should be in line with the current national standards "building design fire code" (GBJ16) and "high-rise civil building design fire code" (GB50045) the relevant provisions.
1, the stairwell design should be in line with the current national standards "building design fire code" (GBJ16) and "high-rise civil building design fire code" (GB50045) the relevant provisions.
2, the net width of the staircase section should not be less than 1.10 m. Six floors and six floors of the following residential, one side of the staircase section with a balustrade net width should not be less than 1m.
Note: The net width of the stair section refers to the horizontal distance between the wall and the centre of the handrail.
3, the width of the stair tread should not be less than 0.26m, the height of the tread should not be more than 0.175m. the height of the handrail should not be less than 0.90m. the length of the horizontal staircase balustrade is more than 0.50m, the height of the handrail should not be less than 1.05m. the headroom between vertical bars of the staircase balustrade should not be more than 0.11m.
4, the net width of the staircase platform should not be less than the net width of the staircase section, and shall not be less than 1.20 m. The vertical height of the staircase platform from the lower edge of the structure to the pedestrian passage should not be less than 2 m. The difference in height between the entrance floor and the outdoor ground should be not less than 0.10 m. The height difference between the entrance floor and the outdoor ground should be not less than 0.10 m.
5、When the net width of the stairwell is greater than 0.11m, measures must be taken to prevent children from climbing and slipping.
6, seven or more residential or residential entrance floor from the outdoor design of the floor height of more than 16m above the ground must be set up lifts.
Note:
(1) For multi-storey residential buildings with the ground floor used as shops or other rooms, lifts must be installed when the height of the floor of the entrance level of the residents from the outdoor designed ground level of the building exceeds 16m.
(2) If the ground floor is used as an elevated floor or storage space for multi-storey residential buildings, lifts must be installed when the floor of the entrance level of the residents is more than 16m away from the outdoor design ground height of the building.
(3) The top floor is a two-storey set of leaping residence, the part of the leaping floor does not count the number of floors. If the height of the entrance floor of the top floor from the outdoor design ground of the building does not exceed 16m, the lift may not be provided.
(4) When the middle floor of the residence has a direct access to the outdoor ground and a fire escape, the number of floors can be calculated from the middle floor.
7, twelve floors and above the high-rise residential, each building should not be less than two sets of lifts, which is appropriate to configure a stretcher can be accommodated in the lift.
8, high-rise residential lift should be set up on each floor. When the residential lift is not set up on each floor, the number of floors without station should not exceed two. Tower and corridor type high-rise residential lift should be arranged in groups. Unit-type high-rise residential units only one lift per unit should be used to contact the corridor connection.
9, the depth of the waiting hall should not be less than the depth of the largest car box in multiple lifts, and should not be less than 1.50m.